Minimum Cover

Subject to Engineering Design Approval, the following table reflects industry standards (AS/NZS 2566.2:1998) in the minimum cover recommended.

Loading ConditionMinimum cover (m)
Not subject to vehicular loading0.3
Land zoned for agricultural loading0.6
Subject to vehicular loading 
(a) no carriageway0.45
(b) sealed carriageway0.6
(c) unsealed carriageway0.75
Pipelines in embarkments or subject to construction equipment loads0.75

Note that for pipes installed in Easements, for Utilities, Public Infrastructure, or owned/operated by Local Authorities- other minimum cover requirements may apply.